Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Articles

Bradford-White Water Heaters - Atmospheric

BRADFORD-WHITE Gas (Natural) Water Heating | ATMOSPHERIC VENT ENERGY  SAVER MODELS (requires a chimney) in Seattle

 

DEFENDER SAFETY SYSTEM®

29-60 gallon sizes

 

 M-I-5036FBN

Most Common

Lowest Price

60% +- Fuel Efficient

These water heaters utilize a draft diverter and are atmospherically vented with capacities ranging from 29 to 60 gallons and inputs ranging from 30,000-50,000 BTU's. These models are perfect for many standard water heating applications.

  • 10 Models (29-60 gallon capacities)
  • 30,000-50,000 BTU/Hr.
  • FVIR Defender Safety System®

(Sample model numbers include:M‑I‑303T6FBN, M‑I‑40T6FBN, M‑I‑5036FBN)

Bradford White ICON System™ Features

  • Enhanced Performance
  • Advanced Temperature Control System
  • Intelligent Diagnostics
  • Pilot On Indication
  • Green LED
  • Separate Immersed Thermowell

Standard Energy Saver Features

  • Advanced ScreenLok® Technology Flame Arrestor design
  • Resettable thermal switch
  • Maintenance free
  • Pedestal base
  • Sight window
  • Factory installed Hydrojet® Total Performance System
  • Vitraglas® lining
  • ¾" NPT factory installed dielectric waterway fittings
  • Protective magnesium anode rod
  • "3" x "4" Snap-Lock draft diverter on 40,000 BTU/Hr. or less models
  • T&P relief valve included
  • Brass drain valve
  • 1" Non-CFC foam insulation

HIGH INPUT

75 & 100 gallon sizes

ATMOSPHERIC VENT ENERGY SAVER MODELS

M-I-100T-65X

60% +- Fuel Efficient

 

These models also utilize a draft diverter and are atmospherically vented, however they offer larger gallon capacities and higher recovery rates. This translates to an increased amount of hot water available at a usable temperature in less time then normal.

  • 2 Models (75 and 100 gallon capacities)
  • 76,000-85,000 BTU/Hr.

(Sample model numbers include: M‑I‑75S6BN, M‑I‑100T6BN)

Bradford White ICON System™ Features

  • Enhanced Performance
  • Advanced Temperature Control System
  • Intelligent Diagnostics
  • Pilot On Indication
  • Green LED
  • Separate Immersed Thermowell

Standard Energy Saver Features

  • Pedestal base (M-I-75 only)
  • Factory installed Hydrojet 2™ Total Performance System
  • Vitraglas® lining
  • ¾" NPT side connections
  • Non-CFC foam insulation
  • M-I-75 has 1" NPT & M-I-100 has 1¼" NPT factory installed dielectric waterway fittings
  • Protective magnesium anode rod
  • 4" "Snap Lock" draft diverter
  • T&P relief valve installed
  • Brass drain valve

EXTRA RECOVERY

40-60 gallon sizes

DEFENDER SAFETY SYSTEM®
ATMOSPHERIC VENT ENERGY SAVER MODELS

M-2-XR65T6FBN

 

These models also utilize a draft diverter and are atmospherically vented, however they offer Extra Recovery. This translates to an increased amount of hot water available at a usable temperature in less time than normal.

  • Extra Recovery - More hot water in less time!
  • 3 Models (40-65 gallon capacities)
  • 40,000-65,000 BTU/Hr.
  • FVIR Defender Safety System®
  • (Sample model numbers include:M‑1‑XR403S6FBN, M‑2‑XR504T6FBN, M‑2‑XR65T6FBN)

    Bradford White ICON System™ Features

    • Enhanced Performance
    • Advanced Temperature Control System
    • Intelligent Diagnostics
    • Pilot On Indication
    • Green LED
    • Separate Immersed Thermowell

    Standard Energy Saver Features

    • Advanced ScreenLok® Technology Flame Arrestor design
    • Resettable thermal switch
    • Maintenance free
    • Pedestal base
    • Sight window
    • Factory Installed Hydrojet® Total Performance System
    • Vitraglas® lining
    • ¾" NPT factory installed dielectric waterway fittings
    • Protective magnesium anode rod
    • ¾" NPT side connections for space heating
    • 4" Snap-lock draft diverter
    • T & P relief valve included
    • Brass drain valve
    • 2" Non-CFC foam insulation (1" on M1 models)

    HIGH EF DAMPER

    DEFENDER SAFETY SYSTEM®

    ATMOSPHERIC VENT

    ENERGY SAVER MODELS

    avedss hief atmos vent 120b

     

    These models feature an automatic flue damper that helps to reduce stand-by heat loss. The flue damper, combined with additional insulation and heat traps, helps these units achieve the highest energy factor (EF) rating of our atmospheric vent models. These models qualify for the current Energy Star EF requirement and for the September 1st, 2010 EF requirement, as well as most utility company rebate programs.

    • High Energy Factor (EF) Ratings- These models qualify for most energy rebate programs as well as the current Energy Star EF requirement and for the September 1st, 2010 EF requirement.
    • 2 Models (40 & 50 gallon capacities)
    • 38,000 - 40,000 BTU/Hr.
    • FVIR Defender Safety System®

    (Sample model numbers include: D‑4‑403S6FBN, D‑4‑504S6FBN)

    Standard Energy Saver Features

    • Honeywell self diagnostic electronic gas control
    • Advanced ScreenLok® Technology Flame Arrestor design
    • Resettable thermal switch
    • Flammable vapor sensor
    • Automatic Flue Damper
    • Compatible with Optional Accessory Packages
    • Factory installed Hydrojet® Total Performance System
    • Vitraglas® lining
    • ¾" NPT factory installed dielectric waterway fittings
    • Protective magnesium anode rod
    • "3" x "4" Snap-Lock draft diverter
    • T&P relief valve included
    • 2" Non-CFC foam insulation
    • Low restriction brass drain valve

    Evan Conklin Plumbing & Heating Inc. (206) 793-8303

    Copyright © 2012 evanconklinplumbing.com. All Rights Reserved.